HF receiver PT-100 Rx-Ts (Dig)

HF receiver PT-100 Rx-Ts (Dig)

HF receiver PT-100 Rx-Ts  (Dig)
Digital automated MF-HF radio receiving sets

Area

Purpose of the equipment

Radio receiving sets MF-HF ranges provide reception of information using the principles of digital processing of radio frequency signals and switching of digital streams. The radio receiving set is intended for use as part of automated HF radio stations operating in adaptive simplex and duplex modes in automated radio centers, as well as in case of stand-alone use.
The receiver can receive both analogue signals (telephone and telegraph) and digital signals in the frequency range from 0.1 to 30 MHz.

Versions of Radio Receiving Sets

ЖЯ 2.000.129-04 - PT-100 Rx-Ts (for use in fixed installations)
ЖЯ 2.000.129-05 - PT-100 Rx.1-Ts (rack version)
ЖЯ 2.000.129-06 - PT-100 Rx- TsA (version for use in stationary facilities)

Main Technical Characteristics

The receiver provides:
• remote control (RC) from the external unit via interface RS-232C at a rate of 9600 bps, as well as via interfaces RS-422/485, Ethernet;
• local control on the front panel;
• availability of analogue (HF-128±20 kHz and TF) and digital (standard IEEE 802,3 1000 BASE) outputs;
• reception of signals of emission classes in accordance with the table.

Main technical characteristics:

Operating frequency range 0,1-30 MHz
Number of memorable frequency channels 100
Emission classes R3E, J3E, J7B, F1B (TF-500, TF-170), A1A, G1B
Minimum frequency tuning step in the range from 0.4 to 29.999999 MHz 1 Hz
Tuning time before setting the nominal level of AGC signal no more than 3 dB
Group-delay flatness of SSB channel from 350 to 2700 Hz and from 300 to 3400 Hz 20 ms
Tuning time in the absence of a signal at the receiver input 5 ms
Frequency stability
- in 5 minutes after switching on
- daily, in 4 hours after switching on
- in the operating temperature range

±1*10-7
±5*10-9
±1*10-7
Noise ratio in the range from 0.4 to 229.999999 MHz 12 dB
AGC range of the spectrum of the information signal when the output signal changes by no more than 6 dB 90 dB
Dynamic range of the 3rd order from 0.4 to 29.999999 MHz and at frequency detuning of ±50/100 kHz with respect to the operating frequency 80 dBµV
Adjacent channel selectivity at squareness ratio:
1,5
2,5
5
10

60 dB
70 dB
80 dB
90 dB
AGC and MGC range 90 dB
Operating conditions for groups 1.1. 1.3 and GOST RV 20.39.304
Operating temperature
Limit temperature

-10…+55 °С
40…+70 °С
MTBF 10 000 h
Service life 20 years
Power consumption from 220 V mains 41 W
Dimensions (WxHxD), mm:
Version ЖЯ2.000.129
Version ЖЯ2.000.129-01
Version ЖЯ2.000.129-02

249х147,5х376
482,6х132,6х365
276х168х376
Weight
Version ЖЯ2.000.129-04
Version ЖЯ2.000.129-05
Version ЖЯ2.000.129-06

7,5 kg
9 kg
10 kg
Control remote by PC via interface RS-232C, Ethernet
Automatic self-test with information display on the control PC